Overview of Browser Access Applications

When users log in to the Browser Access Portal, they see all the Browser Access applications according to their access permissions. You can customize the name and icon for each application in the portal. When a user clicks an application, the application opens in a new window and the authentication token is used to log in users with SSO. If the authentication token is valid, then users can also directly enter the application URL to open the application without the portal.

This is an example of a Browser Access Portal:

SDP_Portal.png

Note

Note: Browser Access applications don’t support NTLM authentication.

Adding Internal Applications

When you add a new application that's hosted on an internal server, define the URL for users to directly access the application without using the portal. After you define the external URL prefix for the application, you can configure the following settings:

  • Base path of URLs that can access the application, this is a security feature that prevents access outside of this path

  • Internal IP address or host name, and internal port number for the application

  • Custom HTTP or HTTPS (TLS SNI) header for the application

You also have the option to configure the Landing Page for the application.

Later you can edit the application and configure the look and feel in the Browser Access Portal.

Defining the Internal Address for the Application

You can customize the HTTP header, or TLS SNI for HTTPS, to support different deployments for internal servers. The following list summarizes the options to define the Internal address for Browser Access applications:

  • Option 1 - Don't customize the header, and configure the Host Address with the IP address that is used to connect to the internal server. You don't define the Host Name field.

  • Option 2 - Define the Host Name for the application which is added to the header. The Host Address (IP address or host name) is used to resolve the address or connect to the application.

  • Option 3 - Configure the Host Address with the host name that is used to connect to the internal server. This host name is added to the header, and you don't define the Host Name field. Cato sends DNS queries for the host name to the DNS servers configured for the account with source IP 10.254.254.1 (or the corresponding IP address). If configured, DNS Forwarding rules are applied for the DNS queries.

Sample Configurations for Custom Internal Address

This section shows sample configurations for each of the Internal host options.

Defining Host Address with an IP Address (Option 1)

Internal_Host_-_Option_1.png

In the screenshot above, the Host Address is 10.20.20.20 and it is also used to connect to the application. There is no change to the HTTP header, or SNI.

Defining Host Address with a Hostname and Adding a Host Name (Option 2)

In the screenshot above, the Host Address is gandalf.local and the Host Name for the application is samplehost.local. gandalf.local is used to resolve the address, and samplehost.local is added to the HTTP header, or SNI.

Internal_Host_-_Option_2.png

Defining Host Address with an IP Address and Adding a Host Name (Option 3)

In the screenshot above, the Host Address is 10.20.20.20 and the Host Name for the application is samplehost.local. 10.20.20.20 is used to connect to the application, and samplehost.local is added to the HTTP header, or SNI.

Internal_Host_-_Option_3.png

Configuring the New Internal Application

Add a new application to the Applications window and define the settings for it. You can configure the look-and-feel, choose the Icon that is shown in the Browser Access Portal and the Description for the hover text.

You can enable the Use source NAT IP range option to define the translated source IP addresses for this application. For example, applications that use an Access Control List (ACL) to only allow connections from a specific IP range and admins that only use specific IP addresses in the network.

Note

Note: If the Use source NAT IP range option is grayed out, then you need to configure the NAT IP Range setting in the Browser Access > Settings tab or section.

To add a new application to the Browser Access Portal:

  1. From the navigation menu, click Access > Browser Access.

  2. From the Applications tab or section, click New.

    The Edit Application panel opens.

  3. Enter the application Name for the Browser Access Portal.

  4. Enter a Description to configure the hover text for the application in the Browser Access Portal.

  5. Configure the settings for the application URL:

    • (Optional) Application Landing Page for the users

    • (Optional) Base Path for the application, resources outside of this path are blocked and users can't access them

    • URL prefix that is added to the beginning of the URL

  6. In Icon, upload the file with the icon for the application.

  7. To enable the Browser Access Portal to translate the source IP address for an application, select Use source NAT IP range.

  8. Configure the Internal Host settings for the application:

    1. In Host Address, enter the IP address or host name for the internal server that hosts the application.

      When you define a host name as the Host Address, then it is added to the header. Otherwise, the IP address is used to connect to the internal server

    2. Enter the internal Port for the application.

    3. Select the Protocol, HTTP or HTTPS.

    4. (Optional) Enter the Host Name for the application server.

      The Host Name is added to the header.

  9. Click Apply, and then click Save.